Monitored data points
Parameters available in the MelPump dashboard and reports. The "Control" column shows if you can also change the value from the app.
| Parameter | Description | Monitor | Control |
|---|---|---|---|
| COP | Efficiency ratio - heat output divided by electricity input | check_circle | remove |
| Compressor Frequency | Speed of the compressor in Hz, higher values mean more heating or cooling power | check_circle | remove |
| Compressor Frequency | Speed of the compressor in Hz, higher values mean more heating or cooling power | check_circle | remove |
| Condensing Temp | Internal heat pump temperature where refrigerant releases heat to the water system, higher values usually mean lower efficiency | check_circle | remove |
| Delta Temp | Difference between the water leaving and returning to the heat pump, used to show how much heat is being transferred | check_circle | remove |
| Target Tank Water Temp | Desired domestic hot water tank temperature | check_circle | tune |
| Tank Water Temp | Current temperature of the domestic hot water stored in the tank | check_circle | remove |
| Target Tank Water Temp | Desired domestic hot water tank temperature | check_circle | tune |
| Input Power | Estimated electrical power being consumed | check_circle | remove |
| Output Power | Estimated heat energy being produced | check_circle | remove |
| Brine Inlet Temp | Temperature of the ground loop fluid entering the heat pump | check_circle | remove |
| Brine Outlet Temp | Temperature of the ground loop fluid leaving the heat pump | check_circle | remove |
| Fan 1 RPM | Speed of the first outdoor unit fan | check_circle | remove |
| Error Code | Diagnostic code shown when there is a problem | check_circle | remove |
| Has Error | Indicates if the system has an active error | check_circle | remove |
| Compressor Frequency | Speed of the compressor in Hz, higher values mean more heating or cooling power | check_circle | remove |
| Flow Rate | Amount of water flowing through the system in litres per minute | check_circle | remove |
| Flow Rate | Amount of water flowing through the system in litres per minute | check_circle | remove |
| Target Temp #1 | Target water temperature for the heating circuit in zone #1 | check_circle | remove |
| Indoor Temp #1 | Current air temperature in rooms served by heating zone #1 | check_circle | remove |
| Thermostat Temp #1 | Desired room temperature set for heating zone #1 | check_circle | remove |
| Operation Mode #1 | Operating mode for heating zone #1. In most heat pumps this is either constant flow or compensation curve mode, but some models may support advanced modes like auto-adaptation. | check_circle | tune |
| Return Temp | Water temperature returning to the heat pump from the heating system | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | tune |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | tune |
| Outdoor Temp | Current outside air temperature measured near the heat pump | check_circle | remove |
| Fan 1 RPM | Speed of the first outdoor unit fan | check_circle | remove |
| Flow Temp | Water temperature leaving the heat pump and going into the heating system | check_circle | remove |
| Target Temp #1 | Target water temperature for the heating circuit in zone #1 | check_circle | remove |
| Liquid Line Temp | Temperature of the liquid refrigerant flowing through the heat pump's cooling circuit | check_circle | remove |
| Lev A | Electronic expansion valve opening position | check_circle | remove |
| Lev A | Electronic expansion valve opening position | check_circle | remove |
| Power | Whether the heat pump is turned on or off | check_circle | remove |
| Indoor Temp #2 | Current air temperature in rooms served by heating zone #2 | check_circle | remove |
App-level features
Automation and optimization modes that MelPump unlocks for this integration.
bolt
Solar Mode - Zone Heating
bolt
Advanced Scheduler
bolt
Push and Email Notifications
bolt
Energy Estimation